Arithmetic Operators
operations abbreviation time
Addition + 0.26 ms
Subtraction - 0.26 ms
Multiplication * 0.26 ms
Division / 0.26 ms
Modulo % 0.24 ms
Truncate value trunc 0.16 ms
Minimum value min 0.16 ms
Maximum value max 0.16 ms
Absolute value abs 0.16 ms
Square root sqrt 0.26 ms
Exponential function to base e exp 0.56 ms
Logarithm to base e In 0.26 ms
Logarithm to base 10 log 0.26 ms
Sine sin 0.44 ms
Cosine cos 0.44 ms
Tangent tan 0.66 ms
Inverse sine arcsin 0.70 ms
Inverse cosine arccos 0.70 ms
Inverse tangent arctan 0.62 ms
Lowest value from a selection Low 0.30 ms
Highest value from a selection high 0.30 ms
X
Y
power 1.64 ms
Integrator integ 0.18 ms
Differentiator deriv 0.18 ms
Read from external module read
Write to external module write
Time /seconds of the day) SecondsOfDay 0.18 ms
Sample rate SampleTime 0.18 ms
Free space on SD-Card SDSpace 0.20 ms
Hardware Manual COMBILOG 1022
56